MODEL CMA-180 Installation & Operation Rev 2.06BOwner’s Manual Keep with machine for reference 800-854-6417 FAX 714-895-2141CMA DISHM
2.2.5. Water Tempering Kit (Optional) MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.06B Page 9
2.2.6. Installation Checklist Dishmachine checked for concealed damage. Hot water supply is 140° (60°C) Incoming water supply line
minimum. The rinse temperature must be 180°F minimum. If necessary, adjust the temperatures by removing the panel in front of the respective heater
2.2.8. Electrical Requirements The CMA-180 comes standard factory, wired for 3-phase operation. Check the electrical data plate to confirm this.
3. Wiring Options 3-Phase and 1 Phase Wiring Options Single-Source 220V 3-Phase (20 amp/12 g*) (Without booster) Single-Source 220V 3-Phase
4. Quick service guideMODEL CMA-180 INSTALLATION & OPERATION Rev. 2.06B Page 14 MODEL: CMA 180 HIGH TEMP TECHNICAL ISSUE CAUSE SOLUTION Door ma
5. INITIAL PARTS KIT P/N 1100.17 P/N DESCRIPTION NO. REQ’D 00121.18 CMA-180 Drain Stopper O Ring 1 00200.10 Pump Assy 110/220V 60 Hz (Open
6. Auto-Fill Solid State Timer 1236 AUTO-FILLSWITCHWATERSOLENOIDVALVEWASH PUMPCONTACTORT1T2L1L2violetvioletorangebluebluered Pre-selected delay p
7. Wire Diagram for CMA-180 With Booster Heater MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.06B Page 17
8. Wire Diagram for CMA-180 Booster Only WASH PUMPCONTACTORT1T2L1L2GROUNDPUMPMOTORWASH TANKHEATERHEATERCONTACTORT1T2T3L1L2L35kWBOOSTERHEATERCONTACTO
Table of Contents Model CMA-180 1. SPECIFICATIONS... 2
9. Wire Diagram for CMA-180 Without Booster Heater MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.06B Page 19
10. Wire Diagram for 480V 180 Without Booster Heater MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.06B Page 20
11. Wire Diagram for 480V 180 With Booster Heater MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.06B Page 21
1. Specifications 1.1 CMA-180/CMA-180T Metric Equivalent WATER CONSUMPTION PER RACK .96 G/1.24 G (3.6 L/4.65 L) PER HOUR 52 G/74.4 G (197 L/28
1.1. CMA-180/CMA-180T ELECTRICAL RATING VOLTS PHASE AMPS WITHOUT BOOSTER 208 1 28/36 240 1 30/38 208 3 19/24 240 208 240 208 ELECTRICAL RAT
2. Getting Started 2.1. Introduction to CMA-180 The CMA-180 is a hot water sanitizing, single rack, door-type dishmachine. It is a stand-alone mac
2.2. Receiving and Installation Step 1: Remove packaging material. Step 2: Remove service manual and machine legs from inside the wash tank. St
ii. Run your dispenser wires through the conduit to the control box. iii. Run your probe wires to the control box. iv. With the machine’s power “
2. Remove the plug from the mixing chamber located by the vacuum breaker on the back of machine; and install the rinse injection fitting (supplied
2.2.4. Exhaust Fan Control Kit p/n 17528.00 Instructions 1. Connect terminal #1 on timer block (Red) to heater contactor terminal marked L3 2. C